Air purifiers for schools and nurseries
25 people in 60 square metres, six hours a day. TU Berlin simulated exactly this room for dp. dp hangs from the ceiling, out of children's reach, and filters the air in the whole classroom.
- TU Berlin simulation in the classroom
- HEPA H14 · ≥99.995% (MPPS)
- Out of children's reach
- Developed in Germany

Made for full rooms
A floor-standing unit in the corner mainly cleans the air close to it – and gets in children's way.
Scientifically simulated
TU Berlin simulated a 60 m² classroom with 24 pupils and one teacher: with dp on the ceiling, air cleaning was more even than with a mobile unit.
Safe for children
No cable on the floor, no unit to knock over, no filter compartment at child height. dp hangs from the ceiling.
No conversion work, no noise during lessons
Installed like a ceiling light. You choose the fan setting so that lessons are not disturbed.
This is what dp looks like in use
No renderings: these units hang at our customers' sites and run every day.











How much airflow does your room need?
A classroom with 60 m², a 3 m ceiling and 25 people: 180 m³ room volume × 4 air changes per hour = 720 m³/h, plus 25 × 21 m³/h for the people – 1,245 m³/h in total. Recommendation: 2 × dp X.
How we calculate: room volume × air changes per hour (residential 3, commercial 4, medical 5) plus 21 m³/h per person. A dp R is intended for rooms of up to 45 m² and delivers approx. 380–400 m³/h in normal operation; the maximum of 550 m³/h is noticeably louder. We plan a dp X quietly at approx. 850 m³/h (e.g. in a classroom); 1,000–1,200 m³/h is possible, 1,500 m³/h maximum. We will clarify the right setting and how quietly the unit then runs during the consultation.
“It works – and that is what matters most in school buildings.”
“The air-purifying ceiling light is ideal equipment for our school buildings to ensure good indoor air quality. The units are screwed to the ceiling and do not disturb lessons. There are no cables lying on the floor, it is almost silent, it looks good – and above all: it works. […] Used air rises, so it has to be drawn in at the ceiling – and the cleaned air comes back down via the ceiling. dp has worked this out brilliantly and created a product whose properties are unique. We have installed it everywhere.”
Excerpt from the video interview of April 2021 (English translation of the German original). The video only loads from YouTube when you click it.
Listen to the statement – in your language:
dp R or dp X?
For a typical classroom with 25 people we plan two dp X running quietly at about 850 m³/h – the TU simulation also used two ceiling units.
| Feature | dp R | dp X |
|---|---|---|
| Design | round ceiling light, Ø 445 mm | rectangular, 640 × 540 mm |
| Max. airflow | 550 m³/h | 1.500 m³/h continuous operation 800 m³/h |
| Filter | HEPA H10 + HEPA H14 (≥99.995% at MPPS to EN 1822), activated carbon optional, UV-C LEDs in a closed housing | |
| Light | 3 LED light bands, 2,700–6,000 K | integrated LED lighting |
| Weight | 11 kg | 20 kg |
| Filter life | approx. 2,200 operating hours | approx. 4,200 operating hours |
Simulated, measured, in use
You can read every statement on this page in the original documents.
Airflow simulation of a 60 m² classroom with 25 people: ceiling-mounted dp units compared with a mobile floor-standing unit. Result: more even air cleaning in the occupied zone and a higher level of cleanliness at breathing height.
Read the short report (PDF)The German International School Riyadh uses dp in its rooms and confirms this in a reference letter.
View the reference letterSeparation efficiency of ≥99.995% at MPPS to EN 1822, plus an H10 pre-filter, UV-C LEDs in a closed housing and activated carbon on request. The value describes the filter, not a measured value of the room air.
Technical dataWhat we are asked most often
How many units does a classroom need?
The TU simulation used two ceiling units for 60 m². For a full classroom with 25 people we plan two dp X running quietly at about 850 m³/h; for smaller rooms or fewer people, one dp X or two dp R is enough.
Can you hear the unit during lessons?
The dp R is between 40 and 65 dB depending on the setting. We plan the setting so that enough air is filtered and lessons are not disturbed.
Is it suitable for a nursery nap room?
Yes. During the midday rest dp runs at a low setting; the warm, dimmable light can be turned down.
Does dp replace ventilation?
No. dp filters particles from the air. Fresh outdoor air still comes in through the window or the ventilation system.
Your school or nursery – we plan with you
Tell us the number of rooms, floor area and ceiling height. We will send a proposal for one room or the whole building.