Clinic · Patient room · Isolation · Operating room

Air purifiers for hospitals, patient rooms and operating rooms

In a hospital every room counts: waiting area, patient room, isolation area, operating theatre. The dp X filters the room air from the ceiling with HEPA H14 – in continuous operation, without floor space and without cables on the floor. Its operating manual explicitly names hospitals, including operating rooms, as an area of use.

  • Intended for clinics incl. operating rooms (dp X)
  • HEPA H14 · ≥99.995% (MPPS)
  • Measured in clinical use
  • Air distribution simulated by TU Berlin
Operating theatre with operating table and ceiling-mounted dp air purifier
Operating theatre · installed unit
up to 1,500 m³/hAirflow dp X
800 m³/hContinuous operation dp X
≥99.995%HEPA H14 to EN 1822 (MPPS)
up to 100units networked via program
WHY ON THE CEILING

Built for rooms with high demands

Mobile units get in the way, are moved and unplugged. dp is fixed to the ceiling and keeps running.

Intended for clinical use

According to the operating manual, the dp X is intended for hospitals including operating rooms. HEPA H14, UV-C in a closed housing, continuous operation at 800 m³/h.

Already in isolation and infection areas

dp units hang in operating theatres, on a special tuberculosis ward and in an isolation room for infectious diseases.

Central control instead of switching units one by one

Up to 100 units can be networked via a program. You see filter status and operation in the app – no ladder needed.

REAL INSTALLATIONS

This is what dp looks like in use

No renderings: these units hang at our customers' sites and run every day.

Operating theatre – unit above the OR equipment
Operating theatreUnit above the OR equipment
Special tuberculosis ward – rectangular unit in the ward area
Special tuberculosis wardRectangular unit in the ward area
Isolation room – infection isolation room with dp
Isolation roomInfection isolation room with dp
Ward corridor – unit above the nursing area
Ward corridorUnit above the nursing area
Patient room – dp in the patient room
Patient roomdp in the patient room
Operating theatre – second operating room with dp
Operating theatresecond operating room with dp
PLANNING IN 30 SECONDS

How much airflow does your room need?

A patient room with 20 m², a 3 m ceiling and 2 people: 60 m³ room volume × 5 air changes per hour = 300 m³/h. Recommendation: 1 × dp R.

How we calculate: room volume × air changes per hour (residential 3, commercial 4, medical 5 – planning recommendation by dp). For very high occupancy we plan the sizing individually with you. A dp R is intended for rooms of up to 45 m²; 550 m³/h is its maximum airflow. We plan a dp X with up to 1,200 m³/h per unit. We agree the mounting position and operating level with you during the consultation.

Room volume 90 m³
Required airflow 300 m³/h
Recommendation: 1 × dp R
CHOOSING A MODEL

dp R or dp X?

The dp R suits small clinics, waiting areas, patient and ward rooms. For operating theatres, isolation and intensive care areas we recommend the dp X: it moves almost three times as much air and is designed for the usually larger rooms.

Featuredp Rdp X
Designround ceiling light, Ø 445 mmrectangular, 640 × 540 mm
Max. airflow550 m³/h1.500 m³/h
continuous operation 800 m³/h
FilterHEPA H10 + HEPA H14 (≥99.995% at MPPS to EN 1822), activated carbon optional, UV-C LEDs in a closed housing
Light3 LED light bands, 2,700–6,000 Kintegrated LED lighting
Weight11 kg20 kg
Filter lifeapprox. 2,200 operating hoursapprox. 4,200 operating hours
EVIDENCE, NOT PROMISES

Simulated, measured, in use

You can read every statement on this page in the original documents.

Saroj Hospital, New Delhi · 06.11.2025
−42% particles 0.3 µm

Patient cubicle with dp X, measured with a Trotec PC200 particle counter: 133,701 before the start, 77,438 after about 20 minutes of operation. A single short measurement; all size classes are listed in the report.

View the measurement report (PDF)
TU Berlin · Hermann Rietschel Institute · 2021
More even air cleaning

Airflow simulation of a 60 m² classroom with 25 people: ceiling-mounted dp units compared with a mobile floor-standing unit. Result: more even air cleaning in the occupied zone and a higher level of cleanliness at breathing height.

Read the short report (PDF)
References
Signed

Reference letters and measurement reports from clinics in New Delhi, Tehran and Kashan are available for download in the media centre.

All evidence in the media centre
FREQUENTLY ASKED QUESTIONS

What we are asked most often

May the dp X be used in the operating room?

The dp X operating manual names hospitals, including operating rooms, as an area of use. The dp X complements the operating room's ventilation and air-conditioning system (to DIN 1946-4) – it does not replace it. We coordinate the planning with your hospital hygiene team and building services.

And the dp R?

The dp R is the choice for small clinics, waiting areas, patient and ward rooms. For the operating room we recommend the dp X – with up to 1,500 m³/h instead of 550 m³/h it has the airflow needed for large rooms with high demands.

How is it controlled and maintained?

Via app, remote control or program, up to 100 units in a network. The dp X filter lasts approx. 4,200 operating hours; the app shows the status and warns in good time.

What about UV-C?

The UV-C LEDs sit in a closed housing and irradiate the air inside the unit, not the room.

FREE PLANNING

Your clinical area – we plan it with you

Tell us the area, floor space and ceiling height. We agree model, number of units and operating level with you and your building services.