Industry · Control room · Laboratory · Break room

Air purifiers for industry, control rooms and laboratories

In the control room people work around the clock, and on site the air is rarely as clean as in the office. dp hangs above the workstations, filters with HEPA H14 and up to 100 units can be controlled centrally.

  • Installed in chemical control rooms
  • HEPA H14 · ≥99.995% (MPPS)
  • Up to 100 units networked
  • Developed in Germany
Industrial control room with two ceiling-mounted dp units
Control room · two installed units
24/7Continuous operation in shift work
up to 1,500 m³/hAirflow dp X
up to 100units networked via program
≥99.995%HEPA H14 to EN 1822 (MPPS)
WHY ON THE CEILING

For rooms that never close

Control rooms and laboratories run in shifts. A unit that hangs from the ceiling and is controlled centrally fits right in.

Proven in shift operation

dp units run in control rooms of the chemical industry – around the clock, above the workstations.

Central control

Up to 100 units networked via program, filter status per unit in the app. Planned maintenance instead of surprises.

Activated carbon for odours

Optionally with an activated carbon filter that reduces odours and selected gaseous substances.

REAL INSTALLATIONS

This is what dp looks like in use

No renderings: these units hang at our customers' sites and run every day.

Chemical plant control room – dp R above the workstations
Chemical plant control roomdp R above the workstations
Commissioning – technician giving instruction in the control room
CommissioningTechnician giving instruction in the control room
Plant office – dp R in the work area
Plant officedp R in the work area
PLANNING IN 30 SECONDS

How much airflow does your room need?

A control room with 80 m², a 3.5 m ceiling and 6 people: 280 m³ room volume × 4 air changes per hour = 1,120 m³/h, plus 6 × 21 m³/h for the people – 1,246 m³/h in total. Recommendation: 2 × dp X.

How we calculate: room volume × air changes per hour (residential 3, commercial 4, medical 5) plus 21 m³/h per person. A dp R is intended for rooms of up to 45 m² and delivers approx. 380–400 m³/h in normal operation; the maximum of 550 m³/h is noticeably louder. We plan a dp X quietly at approx. 850 m³/h (e.g. in a classroom); 1,000–1,200 m³/h is possible, 1,500 m³/h maximum. We will clarify the right setting and how quietly the unit then runs during the consultation.

Room volume 280 m³
Allowance for people (21 m³/h per person)
Required airflow 1.120 m³/h
Recommendation: 1 × dp X
CHOOSING A MODEL

dp R or dp X?

Control rooms, laboratories and break rooms are planned with the dp R or the dp X depending on size. We connect several rooms into one controlled network.

Featuredp Rdp X
Designround ceiling light, Ø 445 mmrectangular, 640 × 540 mm
Max. airflow550 m³/h1.500 m³/h
continuous operation 800 m³/h
FilterHEPA H10 + HEPA H14 (≥99.995% at MPPS to EN 1822), activated carbon optional, UV-C LEDs in a closed housing
Light3 LED light bands, 2,700–6,000 Kintegrated LED lighting
Weight11 kg20 kg
Filter lifeapprox. 2,200 operating hoursapprox. 4,200 operating hours
EVIDENCE, NOT PROMISES

Simulated, measured, in use

You can read every statement on this page in the original documents.

TU Berlin · Hermann Rietschel Institute · 2021
More even air cleaning

Airflow simulation of a 60 m² classroom with 25 people: ceiling-mounted dp units compared with a mobile floor-standing unit. Result: more even air cleaning in the occupied zone and a higher level of cleanliness at breathing height.

Read the short report (PDF)
Filter class
HEPA H14

Separation efficiency of ≥99.995% at MPPS to EN 1822, plus an H10 pre-filter, UV-C LEDs in a closed housing and activated carbon on request. The value describes the filter, not a measured value of the room air.

Technical data
References
Signed

Reference letters from DB Systemtechnik, among others, plus measurement reports from clinical use.

All evidence in the media centre
FREQUENTLY ASKED QUESTIONS

What we are asked most often

Is dp suitable for potentially explosive areas?

No. According to the operating manual, use in potentially explosive atmospheres (Ex zones) and where sparks fly is prohibited. dp belongs in control rooms, laboratories, plant offices and break rooms.

Can dp extract welding fumes or grinding dust?

No. dp cleans the room air but does not replace extraction at the source. Coarse dust in high concentrations would clog the filters quickly.

Does dp filter chemical vapours?

The HEPA H14 filter separates particles. The optional activated carbon filter reduces odours and selected gaseous substances. Your extraction and ventilation systems remain responsible for occupational exposure limits.

How many units can be controlled?

Up to 100 units in a program-controlled network.

How much maintenance is needed?

Filter change on the dp X after approx. 4,200 and on the dp R after approx. 2,200 operating hours. The app shows the status for each unit.

FREE PLANNING

Your site – we plan with you

Tell us the areas, floor space and ceiling heights. We will send you a proposal for units, number and control.

By submitting, you agree that we use your details to process your request. More in our privacy policy.

Thank you! We have received your request and will get back to you shortly.

Sales and product enquiriesVertrieb und ProduktanfragenVentes et demandes de produits

sales@dp-purifier.com