Air purifiers for offices and meeting rooms
Eight hours a day in the same room, meetings with full tables, visitors at reception. dp replaces the ceiling light above the workplace and filters the air in the whole room – without using any floor space.
- Light and air in one unit
- HEPA H14 · ≥99.995% (MPPS)
- DB Systemtechnik reference
- Developed in Germany

Clean air where people work
Workstations change, floor units get moved. dp stays up top and keeps working.
Light and air in one
Three dimmable LED light bands from 2,700 to 6,000 K – warm for meetings, cool for work. Plus HEPA H14 filtration.
Made for meeting rooms
Full tables, closed door: this is where a unit helps that filters the air in the whole room, not just in one corner.
Central control
Via app, remote control or program. Several units in the building can be switched together.
This is what dp looks like in use
No renderings: these units hang at our customers' sites and run every day.




How much airflow does your room need?
An office with 40 m², a 3 m ceiling and 6 people: 120 m³ room volume × 4 air changes per hour = 480 m³/h, plus 6 × 21 m³/h for the people – 606 m³/h in total. Recommendation: 1 × dp X or 2 × dp R.
How we calculate: room volume × air changes per hour (residential 3, commercial 4, medical 5) plus 21 m³/h per person. A dp R is intended for rooms of up to 45 m² and delivers approx. 380–400 m³/h in normal operation; the maximum of 550 m³/h is noticeably louder. We plan a dp X quietly at approx. 850 m³/h (e.g. in a classroom); 1,000–1,200 m³/h is possible, 1,500 m³/h maximum. We will clarify the right setting and how quietly the unit then runs during the consultation.
dp R or dp X?
For single, team and meeting rooms the dp R is the right choice. Open-plan offices and foyers are planned with the dp X or several dp R.
| Feature | dp R | dp X |
|---|---|---|
| Design | round ceiling light, Ø 445 mm | rectangular, 640 × 540 mm |
| Max. airflow | 550 m³/h | 1.500 m³/h continuous operation 800 m³/h |
| Filter | HEPA H10 + HEPA H14 (≥99.995% at MPPS to EN 1822), activated carbon optional, UV-C LEDs in a closed housing | |
| Light | 3 LED light bands, 2,700–6,000 K | integrated LED lighting |
| Weight | 11 kg | 20 kg |
| Filter life | approx. 2,200 operating hours | approx. 4,200 operating hours |
Simulated, measured, in use
You can read every statement on this page in the original documents.
Airflow simulation of a 60 m² classroom with 25 people: ceiling-mounted dp units compared with a mobile floor-standing unit. Result: more even air cleaning in the occupied zone and a higher level of cleanliness at breathing height.
Read the short report (PDF)Reference letters from DB Systemtechnik, among others, plus measurement reports from clinics and schools.
All evidence in the media centreSeparation efficiency of ≥99.995% at MPPS to EN 1822, plus an H10 pre-filter, UV-C LEDs in a closed housing and activated carbon on request. The value describes the filter, not a measured value of the room air.
Technical dataWhat we are asked most often
Does dp replace the office lighting?
The dp R has three dimmable LED light bands and replaces a ceiling light. Whether the lighting alone is sufficient for screen work, we check with you based on the room.
How loud is the unit?
The dp R is between 40 and 65 dB depending on the setting. For offices we choose a setting that is quiet enough for focused work.
Who installs it?
Installed like a ceiling light; the connection is made by a qualified electrician. The dp R weighs 11 kg.
How much maintenance is needed?
Filter change on the dp R after approx. 2,200 operating hours. The app shows the status for each unit.
Your office – request in two minutes
Send us your rooms, floor areas and ceiling heights. We will get back to you with a concrete proposal.