Air purifiers for medical practices and waiting rooms
In the morning every seat is taken, in the afternoon only a few patients sit at reception. dp filters the air from the ceiling, throughout the room and without taking up a single square metre of floor space. We plan the right unit for your practice with you.
- Air distribution simulated by TU Berlin
- HEPA H14 · ≥99.995% (MPPS)
- Measured in clinical use
- Developed in Germany
Made for rooms where many people wait
A floor-standing unit gets in the way and mainly cleans the air close to it. dp works from above, where it bothers no one.
No floor space, no trip hazard
dp hangs in place of a ceiling light. No cable on the floor, nothing in the way of walkers, prams or the cleaning team.
Filtered air throughout the room
Room air is drawn in at the bottom and released at the top in all directions. In the TU Berlin airflow simulation, air cleaning in the occupied zone was more even than with a mobile floor-standing unit.
Light and air in one unit
Three dimmable LED light bands from 2,700 to 6,000 K replace the ceiling light. Control via app or remote, filter status always visible in the app.
This is what dp looks like in practices and clinics
No renderings: these units hang at our customers' sites and run every day.



How much airflow does your waiting room need?
A waiting room with 40 m², a 3 m ceiling and 8 people: 120 m³ room volume × 5 air changes per hour = 600 m³/h. Recommendation: 1 × dp X or 2 × dp R.
How we calculate: room volume × air changes per hour (residential 3, commercial 4, medical 5 – planning recommendation by dp). For very high occupancy we plan the sizing individually with you. A dp R is intended for rooms of up to 45 m²; 550 m³/h is its maximum airflow. We plan a dp X with up to 1,200 m³/h per unit. We agree the mounting position and operating level with you during the consultation.
dp R or dp X?
For the typical waiting room, reception and treatment room, the dp R is the right choice. Large waiting areas and clinics are planned with the dp X.
| Feature | dp R | dp X |
|---|---|---|
| Typical room | Waiting room, reception, treatment room | large waiting areas, clinic, hall |
| Max. airflow | 550 m³/h | 1.500 m³/h continuous operation 800 m³/h |
| Filter | HEPA H10 + HEPA H14 (≥99.995% at MPPS to EN 1822), activated carbon optional, UV-C LEDs in a closed housing | |
| Light | 3 LED light bands, 2,700–6,000 K | integrated LED lighting |
| Sound pressure level | 40–65 dB, depending on setting | on request |
| Weight | 11 kg | 20 kg |
| Filter life | approx. 2,200 operating hours | approx. 4,200 operating hours |
Simulated, measured, in use
You can read every statement on this page in the original documents.
Airflow simulation of a 60 m² room with 25 people: two ceiling-mounted dp units compared with a mobile floor-standing unit. Result: more even air cleaning in the occupied zone and a higher level of cleanliness at breathing height.
Read the short report (PDF)Patient cubicle with dp X, measured with a Trotec PC200 particle counter: 133,701 before the start, 77,438 after about 20 minutes of operation. A single short measurement; all size classes are listed in the report.
View the measurement report (PDF)Reference letters from DB Systemtechnik and the German International School Riyadh, among others, plus measurement reports from clinics in Tehran and Kashan.
All evidence in the media centreThe value ≥99.995% describes the separation efficiency of the H14 filter at MPPS to EN 1822, not a measured value of the room air.
What practice owners ask us most often
Where is the unit installed?
In place of a ceiling light, ideally centred above the waiting area. The dp R weighs 11 kg; the ceiling and fixings must carry this safely. The electrical connection is made by a qualified electrician, just like for a light.
How loud is the unit in the waiting room?
The sound pressure level of the dp R is between 40 and 65 dB depending on the fan setting. We calculate with you which setting your room needs – so you know in advance how quietly the unit runs day to day.
How often does the filter need changing?
For the dp R after approx. 2,200 operating hours. The app shows the remaining filter life and warns at 80% exhaustion. Use only original filters for full filter performance.
Does dp replace ventilation or the hygiene concept?
No. dp complements your practice's ventilation and hygiene measures and continuously filters particles from the room air. It does not replace them.
Your waiting room – request in two minutes
Send us the floor area, ceiling height and the typical number of people. We will check which model and operating level suit your practice and get back to you with a concrete proposal.